Model No.: CMS9000
Brand Name: contec
Means of Transport: TNT, EMS, UPS, FEDEX, DHL

patient Monitor
Multi-parameter (ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate)
Color TFT

CMS9000 Multi-parameter patient Monitor
Features:
1. Color TFT Screen, waveform up to 8 channels
2. Light and portable with build-in rechargeable battery
3. UP to 10 kinds of monitor parameters
4. Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
5. 72 hour storage and review of trend grams and tables, 40 second review of olographic Wavefo RMS.
6. Built-in recorder(option)
7. All-round monitor of adult, pediatric and neonatal.
8. Electrosurgical unit and defibrillation protected
9. Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
10. Option parameters: EtCO2, CO, IBP, Thermal Printer
ECG
1. 5-lead or 3-lead selectable
2. Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
3. Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
4. Gain selection: 12.5mm/s, 25mm/s, 50mm/s
5. Accuracy:? Bpm or? %, whichever is greater
6. Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
7. Calibration signal: 1mV? %
8. Operation modes: Diagnostic, Monitor, Surgery
9. Alarm range: Adult: 15-300bpm
10. Pediatric/Neonatal: 15-350bpm
11. Alarm range: -2.0mV~2.0mV
12. S-T detection: YES, Arrhythmia analysis: YES
13. Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
1. Method: Oscillometry
2. Operation modes: Manual/Automatic/STAT
3. Measurement unit: MmHg/KPa selectable
4. Measurement types: Systolic, Diastolic, Mean
5. Measurement range: Adult: 10-270mmHg
6. Over-pressure protection: YES
7. Resolution: 1mmHg
8. Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
9. Alarm: Systolic, Diastolic, Mean
SpO2
1. Measurement range: 0-100%
2. Accuracy:? Digit (70~100%);
3. 0~69% unspecified
4. Alarm range: 0-100%
Respiration
1. Method: RA-LL impedance
2. Pediatric/Neonatal: 6-150rpm
3. Alarm range: Adult: 6-120rpm
4. Pediatric/Neonatal: 6-150rpm
5. Apnea alarm: YES
Temperature
1. Resolution: 0.1 C
2. Channel: Dual-channel
3. Alarm range: 0-50 C
Option:
EtCO2
1. Measurement Mode: Side-stream or mainstream
2. Measurement range: EtCO2: 0-99mmHg
3. Accuracy: CO2 concentration
4. Apnea alarm: YES
CO
1. Method: Thermo-dilution
2. Measurement range: CO: 0.1-20 lit. /min.
IBP
1. Channel: 2 channels
2. Pressure transducer: Sensitivity: 5( mV/V/mmHg)
3. Transducer sites: ART, PA, CVP, RAP, LAP, ICP
4. Alarm range: -10~300mmHg
bigPhoto
 Ms. serena

Tel: 86-335-8015417
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Contec Medical Systems Co.,Ltd [China (Mainland)]


Business Type:Manufacturer
Country/Region: China (Mainland)

You May Like: